SciELO - Scientific Electronic Library Online

 
vol.54 número3THE INHIBITION MILD STEEL CORROSION IN PHOSPHORIC ACID SOLUTIONS BY 2- PHENYL-1-HYDRAZINE CARBOXAMIDEIDENTIFICATION OF TRITERPENES AND STEROLS FROM PTEROGYNE NITENS (FABACEAE-CAESALPINIOIDEAE) USING HIGH-RESOLUTION GAS CHROMATOGRAPHY índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

Compartir


Journal of the Chilean Chemical Society

versión On-line ISSN 0717-9707

J. Chil. Chem. Soc. v.54 n.3 Concepción  2009

http://dx.doi.org/10.4067/S0717-97072009000300003 

J. Chil. Chem. Soc, 54, N° 3 (2009), págs.; 212-217

 

INFLUENCE OF ENVIRONMENTAL FACTORS IN THE ATMOSPHERIC CORROSION OF COPPER IN THE PRESENCE OF PROPIONIC ACID

 

A. ECHAVARRÍA, F. ECHEVERRÍA*, H. GIL AND C. ARROYAVE

Corrosion and Protection Group, University of Antioquia, Medellin, Colombia. e-mail: fecheve@udea.edu.co


ABSTRACT

Exposure time, pollutant concentration, and relative humidity (RH) are important environmental variables for the atmospheric corrosion of copper in the presence of propionic acid vapors. This paper shows the most outstanding results into the effect of these variables. This study was carried out by mean of exposures at dynamic conditions in 260, 380, and 680 ppbv propionic acid, with relative humidities of 70% and 90%. The effect of the propionic acid was also evaluated in static conditions with 4, 40, and 120 ppmv propionic acid with relative humidities of 40%, 80%, and 100% RH. Allthe samples were evaluated by triplícate within 21 days of exposure. The corrosion rate was usedto quantify the degradation of copper by mean of weight loss and coulometric reduction technique. Coulometric reduction indicates that the charge needed to reduce the oxides increases as exposure time, relative humidity and pollutant concentration increases. On the other hand, the corrosion rate determined gravimetrically, confirms that at a higher relative humidity and higher propionic acid concentration the copper deterioration is also higher.


INTRODUCTION

Volatile organic compounds in the atmosphere (VOC) have different hydrocarbons and organic acid vapors. The most important organic acids in the atmosphere are formic, acetic, propionic, butyric and oxalic acid. The emissions of these types of acids can be either biogenic or anthropogenic, and they contribute to the total acidity of the rain in the urban areas. The corrosion originated by these vapors on different metáis and their alloys (lead, steel, nickel, copper, cadmium, magnesium, zinc) is a phenomenon that has been observed for some time1. Graedel2 finds that the anions of organic acids (acetates and in smaller amount, formates) constitute between 0.1 and 1% of the total ion concentration in the copper patina exposed in outdoor atmospheres by long periods of time. Copper is corroded in presence of organic acids such as formic, acetic and butyric3-10. It has been found that the corrossivity of the organic acids vapors in ppmv (parts per million in volume) level on copper is given in the following order (from the highest to the lowest aggressiveness level) acetic > formic > butyric7,9-10.

On the other hand, the initial growth of corrosion producís on copper has been successfully characterized during exposure to formic acid, acetic acid and propionic acid in ppbv (parts per billion in volume), both quantitatively and chemically, by the combination of IRAS/QCM, electrolytic reduction of corrosion producís and AFM11-13. The results shows the formation of two kind of copper (I) oxides, named crystalline and amorphous identified by coulometric reduction.

Coulometric and potentiodynamic reduction, and corrosion rate measurements by the weight loss method are broadly used techniques for the study of the corrosivity of copper in different environments14-16. The purpose of this laboratory study is to contribute to the understanding of the copper corrosion in presence of propionic acid by mean of reduction charge quantification for the different corrosion compounds formed in this atmosphere. Additionally, coulometric reduction measurements were used to compare them with the gravimetric estimation.

EXPERIMENTAL

Two corrosive atmospheres were evaluated for low and high pollutant concentration17. The first one was carried out in a climatic chamber with a pollutant dosage level of ppbv, under dynamic conditions. Those of high concentration were carried out in a closed chamber (glass vessel) under static conditions.

Exposures performed in climatic chamber— A climatic chamber was used, in which an "oil less" dentistry compressor produced clean air for the experiments. It gives clean air directed to a pretreatment system made of an activated carbón filter, a zero purifier air "PEAK", and two particulate matter filters (0.25 and 0.05 µm). Permeation tubes, used for the liquid propionic acid were calibrated for different emission rates. The permeation was gravimetrically certificated. Usually, values of 90 ± 2% RH and 70 ± 2.5% RH were obtained with a constant air flow of 4 L min-1 . To obtain the desired propionic acid concentration as a vapor, an ideal gas behavior is assumed for the air of the system16. So, the propionic acid concentration in the vapor phase can be calculated as:

where, Cv is the propionic acid concentration expressed in parts per billion in volume (ppbv); ER is the emission rate of the tubes (2650 ± 70, 3750 ± 80 and 6950 ± 100 ng.min-1 ); 29.5 is the molar volume (L.mol-1) of the air in laboratory conditions, 30 °C and 640 mm Hg; 4 is the nominal flow of air (L.min-1) located in Medellin, Colombia 1450 ASL, and 74.08 is the molecular weight (g.mol-1) of the propionic acid (CH3CH2COOH).

Copper samples of dimensions 1.0 x 1.5 x 0.01 cm, Merck (<0.002% Ag, 0.05% Pb, 0.01% Sn, 0.005% Fe, 0.005% Mn, 0.0002% As) were polished with silicon carbide papers up to 600 mesh, degreased with acetone, flushed with cold air, and immediately placed in the exposure chamber. The samples were exposed to propionic acid during 7, 14, and 21 days. The experiments were performed with 260, 380, and 690 ppbv propionic acid.

Exposures performed in closed chamber— Experiments carried out in static conditions were performed at 30 ± 0.8 °C inside a glass vessel dessicators, contained a diluted propionic acid solution. Pollutant concentration of 4, 20, 40, and 120 ppmv propionic acid were used for a duration of 21 days. The solution was renewed weekly to avoid the degradation of the organic compound.

For low relative humidity conditions, the dessicator was provided with a saturated solution of K2CO3.2H20 and NH4C1 to obtain 40% and 80% RH according to ASTM E104-85 standard8,18-19. The relative humidity condition near to 100% was obtained placing a recipient with 500 mL propionic acid solution in the bottom of the dessicator. To produce the propionic acid vapor in static atmosphere, the procedure already described elsewhere, was followed to determine the deterioration of copper in acetic and formic acid atmospheres3-10.

Pollutant concentration of propionic acid vapor in a closed atmosphere was calculated using the relationship between partial pressure and the Raoult's law, adapted from a procedure reported in the literature3-10.

where ρH(Pro) is the partial pressure of the propionic acid in the dessicator's atmosphere, the term is the vapor partial pressure of the puré propionic acid (mm Hg), T is the temperature in Kelvin, G is the propionic acid mass in grams in a 1000 mL solution, MH20 and MH(Pro) are the molecular weights of the water and the propionic acid respectively, and PT is the total pressure under the laboratory's conditions (640 mm Hg for Medellin city).

For exposure in atmospheres with 4, 20, 40, and 120 ppmv (Cv), the amounts of propionic acid and the water used for a volume of 500 mi solution are shown in Table I.


Techniques to measure the corrosion degree—The coulometric reduction technique was carried out according with the ASTM standard B825 - 9713. ACM Instruments Research Potenciostat equipment was used along with a CAR ZRA (Zero Resists Ammeter) to measure the potential of the sample, by using three electrodes with a satúrate calomel electrode (SCE) as the reference and platinum as counter electrode. The electrolytic solution was 0.1 M KC1, purged with Nitrogen for 30 minutes before and during the reductions. The current density was the same in all the measurements, and the value was selected according to the corrosion degree of the sample, so that the reductions were done in less than an hour. Three samples were used to carry out the galvanostatic experiments.

The gravimetric analyses were done using coupons of 0.24 dm2, during 21 days of exposure. The corrosion producís were removed by using an ultrasonic bath in 10% H2S04 (per volume) solution with immersion times of three minutes each sample at room temperature, according to the ASTM Gl - 90 standard17. The measurements were done using an analytical scale with accuracy of ± 0. 1x10-3 g. Three replicas were used during the experiments. The results were statistically treated with the STATGRAPHICS software.

RESULTS AND DISCUSSION

Coulometric reduction curves obtained with dynamic conditions—Fig. 1 shows the coulometric reduction curves of copper samples exposed to 380 ppbv, 90% RH, and 30 °C during 7, 14, and 21 days. The reduction curves were performed at 25 µA.cm-2 current density. A plateau around -0.5 VSCE appeared, corresponding to the amorphous cuprite reduction15-22. This is consistent with previously published results for the same exposure conditions10. A second plateau, close to -0.75 VSCE, can be discerned associated to the intermediate cuprite reduction23, that has been observed in exposures of copper in a clean humidity environment. Finally, we can see a final plateau around -1.15 VSCE corresponding to the hydrogen reduction, that is the final reduction step3-10,15-22. To perform a more complete electrochemical characterization of the copper compounds, it is necessary to calculate the derivative curve of the reduction curves.


Fig. 2 shows the reduction curve and its derivative for a copper sample exposed during 21 days at 680 ppbv. The mínimum of the derivative curve, it is the transition of the reduction between the different oxides, namely amorphous, intermediate , and crystalline cuprite and for last hidrogen. The crystalline cuprite that appears around -IV is seen from Fig. 2, and it was found from all exposure times. These compound is the "bulk" cuprite that is form for longer exposure times23. All the coulometric reduction curves were compared with the electric charge amount, that is, the current density applied times the testing time. Under constant current conditions, the total charge consumed, Q(t), coul. cm-2 , between the beginning of the test and other time could be calculate as:

where I is the current density used in the experiment, A.cm-2 .


Fig. 3 displays the coulometric reduction curves of copper samples exposed in synthetic air at 90% RH after exposure to 260, 360, and 680 ppbv. It is possible to see that, the reduction time increases with increasing the propionic acid concentration. This effect is reflected in a thicker intermediate and crystalline cuprite layer. It is interesting to stress out that, coulometric reduction curves shows detectable changes according to the exposure level, although visually appreciable differences are not observed on the samples evaluated under dynamic conditions (ppbv).


Coulometric reduction curves obtained from static conditions—Figure 4 exhibit the results for copper exposed during static conditions in propionic acid at 100% RH. To obtain the total charge consumed in the reduction of the copper oxides, the ISO TC 156/WG 4 - N 37824 standard criteria was followed. These criteria, allow us to determine the total reduction time from the beginning of the experiment until the hydrogen reduction stage, obtained as the mínimum of the derivative curve of the potential versus time data. The average value of hydrogen evolution (VH -1.03 VSCE) was fixed in these curves. This was performed in order to have a reference of the consumed charge value for the total reduction of the oxides, but also, to compare all the results obtained. The term "Qox" is defined as the charge (coul.cm-2 ) to complete the oxide reduction of the sample.



The corrosion rate measured as the total reduction charge increases with increasing the exposure time. Additionaly, we found higher reduction charge values from the static condition than for the dynamic one, at least at high relative humidities.

Table II shows the charge values for the amorphous cuprite reduction (Cu2O)am, intermediate cuprite reduction (Cu2O)in, and the crystalline cuprite reduction (Cu2O)er deduced from the coulometric reduction curves. The values are calculatedfor21 days of exposure, in both, ppbv (dynamic) and ppmv (static). As itcanbe deduced from Table II, the total electric charge for the oxide reduction; which corresponds to the presence of three type of copper (I) oxide in the sample, increase slightly as the pollutant concentration increases up to 4 ppmv, from 0.0134 to 0.0155 coul.cm-2 . However, a drastic cuprite increase is detected in exposures with 40 ppmv. In this case, the reduction charge was 0.3094 after 21 days.


Effect of the exposure time—The reduction charge (coul.cm-2 ) for the complete reduction of the corrosion producís during the coulometric reduction experiments, lineally increases with increasing the exposure time. This value directly depends on the corrosion product amount. Figure 5 compares the charge values for the reduction in function of the exposure time for three propionic acid concentration in the air (260, 380, and 680 ppbv) at 90% HR and 30°C. The error bars refers to the confidence interval of 95%. In all cases, corrosion rate expressed as reduction charge, increases and it can be discerned for each other. Exposures at 680 ppbv propionic acid produces more corrosion , corresponding with a thicker copper (I) oxide as is seen in Table II.


Figure 6 shows the variation between the reduction charge of the copper oxide in function of the exposure time, for exposures with 4 and 20 ppmv at 100%) HR and 30 °C. In both cases, a lineal behavior is seen, with a greater slope obtained in exposures at 20 ppmv. When comparing with the results from dynamic conditions, see Fig. 5, we can conclude that the static environment produce greater corrosion rates. This may be explained because under static atmospheres, the pollutant remains longer time on the copper surface. Additionally, the relative humidity reach constant values when is controlled into a dessicator, generating enough water monolayers to produce appreciable degradation on the copper surface. But, when it is used dynamic conditions, the relative humidity varies with a relative accuracity of ±5 %, changing the actual water monolayers and producing less corrosion rates.


Effect of the relative humidity and propionic acid concentration—Figure 7 compares the reduction charge against the exposure time for exposures in 260 ppbv with relative humidities of 70 and 90%. It is found that at higher relative humidity the charge value is increased during the reduction; therefore, exist an increment ofthe copper corrosion degree. On the other hand, Fig. 8 shows the gravimetric corrosion rate obtained during dynamic exposures in ppmv level for relative humidities of 40, 80 and 100% and 4, 40, and 120 ppmv during 21 days.



Figure 8 displays variation of the corrosion rate, expressed in mdd (milligram per square decimeter day), for exposures with 4, 40, and 120 ppmv propionic acid and three relative humidity levéis. For relative humidity between 40 and 80%, the corrosion rate is essentially the same, presenting corrosion rates within the standard deviation for the triplicate curves. However, all curves exhibit an increment in corrosion rate when is increase the pollutant concentration when relative humidity passes 80%. Compared with the lower concentration (4 ppmv), the corrosion rates is almost four times with 40 ppmv, and almost ten times with 120 ppmv propionic acid. The same tendency has been found before27. From these results it seems that, 80% of relative humidity is critical for the atmospheric corrosion of copper in presence of propionic acid. The dispersión associated to these results may be related to an inherent error of the acid cleaning performed in the 10% H2S04 solution.


From the coulometric reduction data, the corrosion rate can be estimated using the following formula [4]:

where Qox, coul.cm-2, is the charge for the total oxides reduction, M is the copper molecular weight (63.54 g.mol-1), d is the exposure time (days), F is the Faraday constant (96500 coul.eq-1) and n is the valence number for the reduction (2).

It should be noticed that an n-value of 2 is the one recommended for both, the ISO TC 156/WG 4 - N378 standard24 and the project TROPICORR, to estímate the corrosion rate from the coulometric reduction data25. On the other hand, this n-value has been previously questioned by Rocha et al26, because of an underestimate corrosion rate. So, we propose, in order to get confidence on the corrosion rate, calculate it in function of the total cuprite reduction, including the three types of copper (I) oxides. In this way, the corrosion rate could be estimated as:

Table III shows the comparison between the two corrosion rates estimated by both methods, during a exposure condition of 90%> and 100%> RH. The relation between the corrosion rates deduced using both techniques, approaches to the 1:1 ratio in the lowest corrosion rate values and by general rule, values below 0.05 mdd. The discrepancy in the high values of corrosion rate is evident, where the electrochemical technique predicts much lower estimation that the gravimetric ones. This could be due to an overestimation ofthe corrosion rate due to strong dissolution on the sulphuric acid.


The ability to distinguish between the aggressiveness of the few polluted atmospheres, usually smaller than 700 ppbv, shows that the electrochemical technique is a reliable method to study this type of atmospheres. However, the gravimetric technique is more reliable than the electrochemical one, under high aggressiveness conditions, explained by a greater solubilization of the corrosion producís leading to underestimate values of corrosion rates from the electrochemical data.

Likewise, it can be observed that the degradation rate (slope of the curve Q d) is approximately the same in ppbv concentrations (0.003 coul.cm-2 . day-1 ). But in the ppmv level, the corrosion rate increases with the propionic acid concentration in the air. For exposures with 4 ppmv the slope is 0.004 coul.cm-2 .day-1 and for exposures in 20 ppmv the slope is 0.0108 coul.cm-2 . day-1 (Table III)

Figure 9 compares the corrosion rate gravimetrically determined for the dynamic and static conditions. The data are reported in Table III.


General remarks—Atmospheric corrosion of copper in simulated environments containing propionic acid vapors, seems to be affected by small changes in the pollutant concentration and high relative humidities. These changes were possible to detect by using galvanostatic reduction performed over the corrosion producís present on íhe samples. The reduction lechnique has been successfully applied before lo the characterization and quantification of insoluble copper compounds in several types of environments. In our case, we choose the reduction charge used for the total reduction of the copper (I) oxide as a parameter to estímate the corrosion rate. It was found that the electrochemical technique is very sensible to this environment, and makes it useful to quantify the propionic acid attack. Just one copper oxide was electrochemically identified during the reduction. The copper oxide, exhibits three type of forms, namely amorphous, intermediate , and crustalline cuprite. These oxides were present in all of the experiments. It is reasonable to think that the oxides coexist with organic copper compounds such as any of the copper propionates. The lack of evidence of these organic carboxylates, can be interpreted as an associated high solubility of the organic compounds at least for the pollutant level tested.

Likewise, weight loss technique was used to measure the copper corrosion rate. When comparing the values from dynamic conditions (low pollutant level of ppbv) the data are confident using gravimetric, ISO and Rocha's method (Table III). But, when comparing with the results with static conditions (high pollutant level of ppmv), the values exhibit severe discrepancies making them unreliable to interpret the corrosion process.

Finally, gravimetric data were compared with the electrochemical results, showing some differences. When the traditional weight loss technique is applied to low propionic acid levéis, turns out that the values present an overestimation probably associated to a large metal dissolution. In this case, we proposed to use the total reduction charge as estimation of the real corrosion rate.

The formation of a copper propionate can be proved by mean of complementary electrochemical and non-electrochemical techniques. The authors are currently working in a mechanism that explains the results of copper in presence of propionic acid vapors. In summary, the mechanism could be explained as follows: The first oxide layer cuprite (Cu2O) is instantly formed on the copper surface. This oxide, in presence of adsorbed water is oxidized further to copper oxide (II) (CuO) simultaneously with a pH increase. The hydration of the tenorite layer induces the formation of a hydroxide such as CuO.xH2O. As the pollutant level is increased in the atmosphere, insoluble basic propionate of the type Cu(OH)x(Pro)2-x is formed. Higher concentrations of propionic acid in the atmosphere acidify much more the monolayers and a new compound Cu(Pro)2.H2O begins to precipitate at low pH. The mechanism is based on electrochemical reduction, XPS, XRD and SEM measurements, performed over copper samples from a propionic acid concentration ranging from 10 to 300 ppm. These results have been already published, verifying organic compound and copper oxide and hydroxide as main corrosion producís. A cubic crustalite form of the cuprite is evident for greater corrosion rate27.

CONCLUSIONS

The coulometric reduction technique exhibits, statistically differences (with 95% of confidence) for the reduction charge of the copper (I) oxide obtained during the day 7 and the day 21, at any concentration level of propionic acid. On the other hand, the data indicates an increment of approximately the same order, for the reduction charge value from the results obtained in 260 ppbv, 380 ppbv, and 690 ppbv, at any exposure time. With this technique, it was possible to differentiate the corrosivity of the different environmental conditions evaluated.

The estimation of the corrosion rate by the electrochemical methods is not reliable when some corrosion producís can be solubilized during the coulometric reduction experiments. The high dispersión of the gravimetric corrosion rate under low aggressiveness conditions was probably due to the inherent error related with the acid pickling procedure. However, a higher corrosion rate is observed between the 380 and 690 ppbv compared with 260 ppbv. Copper corrosion is increased slightly with the exposure time, but this deterioration is more evident for high relative humidities and concentrations of propionic acid.

ACKNOWLEDGMENTS

The authors want to express their gratefulness to CSIC/COLCIENCIAS in the project COLCIENCIAS 1115-11500 and to TROPICORR - Tropicalización de Materiales Electro-Electrónicos for the financial support of the study.

 

REFERENCES

1. A. Echavarría, C. Arroyave, E. Cano, F. Echeverría, J. M. Bastidas, Corr. Rev., 21, 395, (2003).

2. Graedel, T. E., Corros. Sci. 27,721(1987).

3. E. Cano, J. M. Bastidas, Metall. Quart., 41, 327, (2002).

4. A. López-Delgado, E. Cano, J. M. Bastidas, F. A. López, J. Electrochem. Soc. 145,4140,(1998).

5. J. M. Bastidas, A. López-Delgado, E. Cano, J. L. Polo, F. A. López, J. Electrochem. Soc. 147, 999, (2000).

6. E. Cano, M. F. López, J. Simancas, J. M. Bastidas, J. Electrochem. Soc. 148, E26, (2001).

7. E. Cano, E. M. Mora, M. Moorish, H. Ascaray, J. M. Bastidas, J. Electrochem. Soc, 151, B207-B213, (2004).

8. E. Cano, J. M. Bastidas, J. L. Polo, N. Mora, J. Electrochem. Soc. 148, B431, (2001).

9. E. Cano, E. M. Mora, H. Azcaray, J. A. López-Caballero, J. M. Bastidas, Proceedings of the Latincorr 2003, Santiago de Chile, Chile, 2003.

10. E. Cano, Proceedings of the IX Conference on Materials Science & Technology, Madrid, España, 2003.

11. H. Gil, C. Leygraf, J. Electrochem. Soc, 154, C272, (2007).

12. H. Gil, C. Leygraf, J. Electrochem. Soc, 154, C611, (2007).

13. C. Leygraf, J. Hedberg, P. Qiu, H. Gil, J. Henriquez, C.M. Johnson, Corrosion, 63, 715, (2007).

14. Anuual Book of ASTM Standads, ASTM B-825-97.

15. S. J. Krumbein, J. Test. Eval, 357, (1989).

16. A. Echavarría, H. Vilca-Meléndez, I. Aoki, Proceedings of the Latincorr 2003, Santiago de Chile, Chile, 2003.

17. Anuual Book of ASTM Standads, ASTM G1-90.

18. H. Vilca-Meléndez, Doctoral Thesis, Escola Politécnica de Universidade de Sao Paulo. (2000).

19. H. Vilca-Meléndez, H, I. Aoki, Proceedings of NACE Brazil, Sao Paulo, 1999.

20. I. Aoki, H. Vilca-Meléndez, F. M. Arruda, A. G. Ceclo, Mater. Sci. Forum, 292, 449, (1998).

21. I. Vieira Aoki and F. Gerjoil, Proceedings of the Corrosion in electro-electronic equipment. Brasil, 2000.

22. A. Echavarría, Doctoral Thesis, Universidad de Antioquia, (2004).

23. T. T. M. Tran, C. Fiaud, E. M. M. Sutter, A. Villanova, Corros. Sci., 45, 2787 (2003)

24. ISO/TC 156/WG4-N358.

25. F. Corvo, J. A. Rocha, CYTED. Productos electro-electrónicos en Ambientes tropicales, J. Rocha ed, Campiñas, 2003.

26. J. A. Rocha, J. Rocha, and I. Aoki, Proceedings of Latincorr 2003, Santiago de Chile, Chile, 2003.

27. A. Echavarría, A. Rueda, E. Cano, F. Echeverría, C. Arroyave, J. M. Bastidas, J. Electrochem. Soc, 150, B140 (2003).

 

(Received: July 21, 2008 - Accepted: May 28, 2009)

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons