SciELO - Scientific Electronic Library Online

 
vol.66 issue1Impact of sentinel lymph node metastases in the treatment of breast cancerCorrelation of preoperative parathormone level with estimated volume and weight of the parathyroid adenoma in patientes with primary hyperparathyroidism author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

Share


Revista chilena de cirugía

On-line version ISSN 0718-4026

Abstract

ANDRADES C, Patricio et al. Coupler® venous mechanic microanastomosis: An important technological contribution to microvascular surgery. Rev Chil Cir [online]. 2014, vol.66, n.1, pp.52-58. ISSN 0718-4026.  http://dx.doi.org/10.4067/S0718-40262014000100008.

Aim: The aim of the present paper is to show the experience of the Plastic Surgery Division at the University of Chile Clinical Hospital, with the Coupler® anastomotic device (Synovis Corp, Birmingham, AL) for venous microanastomoses in patients undergoing reconstructive microsurgery. Material and Methods: A retrospective review of 48 consecutive patients with free flaps between March 2009 and in February 2013. All microsurgical venous anastomoses were performed with the Coupler® device and the arterial anastomoses with interrupted or continuous 9-0 or 10-0 nylon sutures. The collected data were: personal and medical patient information, location of the defect, flap used, vessels diameter, arterial anastomoses, Coupler® used, time of anastomosis, postoperative complications, arterial and venous thrombosis. Results: A total of 48 free flaps were performed for reconstruction of lower extremity (n = 25, 52.1%); head-neck (n = 15, 31%); breast (n = 5, 10.4%) and upper extremity (n = 3, 6.3%). The flaps used were: Anterolateral thigh or ALT (n = 25, 52.1%), Radial (n = 10, 20.8%), Deep Inferior Epigastric Artery Perforator or DIEP (n = 5, 10.4%), Latisimus Dorsi (n = 2, 4.2%), Rectus Abdominus (n = 2, 4.2%), Fibula (n = 2, 4.2%), Scapula (n = 1, 2.1%), and Gracilis (n = 1, 2.1%). The Coupler device average diameter used was 2.51 ± 0.46 mm. The average time for the venous anastomosis was 13.5 ± 7.3 minutes. A total of 4 flaps were lost (8.3%), none due to venous thrombosis. Conclusions: The Coupler® System for venous anastomoses is a safe, effective and quick method for microsurgical anastomoses, it is easy to learn and its implementation should be considered in every microvascular surgery center.

Keywords : Microanastomoses; mechanical device; Coupler®.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License