SciELO - Scientific Electronic Library Online

 
vol.11 número1Desmineralización de la Dentina Inducida por Sacarosa en un Modelo de Biofilm Microcosmo índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


International journal of odontostomatology

versão On-line ISSN 0718-381X

Resumo

CARDOZO, Ricardo et al. Study of the Relationships between Bur Diameter and Dental Implant Diameter. Int. J. Odontostomat. [online]. 2017, vol.11, n.1, pp.113-117. ISSN 0718-381X.  http://dx.doi.org/10.4067/S0718-381X2017000100018.

The bur used to construct the bed where a dental implant is installed is extremely important to treatment success. The aim of this investigation was to analyze the relationship between bur diameter and implant diameter in different areas. A descriptive study was designed to analyze 5 commercial brands currently on the market. The manufacturer's instructions were followed to establish the size and type of bur indicated for the study implants, which were regular, with a width between 3.5 mm and 4.0 mm and a length from 12 mm to 13 mm. Drilling from the most apical region, the first measurement of width was established 3 mm cervically, the lower middle measurement 6 mm cervically, the upper middle measurement at 9 mm and the cervical measurement at 12 mm. A scanning electron microscope was used standardized for all measurements; the data were analyzed using the Shapiro-Wilk test and the t-test, having considering a value of p<0.05 for significant differences. At apical level, all the implants were wider than the bur. The greatest differences between bur width and implant were observed at cervical level, maintaining a relation where the implant was always wider. In medium-sized areas, it was observed that in some systems the burs have a larger diameter than the study implants. A significant relation was established in the apical, upper middle and cervical areas. Bur morphology is related to implant morphology; no implant system is the same as another in terms of the implant-bur relation.

Palavras-chave : Dental implant; bur; primary stability.

        · resumo em Espanhol     · texto em Inglês     · Inglês ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons