vol.140 número1Evolución de las licencias por enfermedad grave del niño(a) menor de un año 2004-2008: certezas e interrogantesLa criopreservación embrionaria en estadios más avanzados de desarrollo disminuye la frecuencia de pacientes con embriones criopreservados y el número de embriones criopreservados índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

Compartir


Revista médica de Chile

versión impresa ISSN 0034-9887

Resumen

DIAZ, Franco et al. Veno-arterial difference of carbondioxide as a predictor of low cardiac output in an experimental pediatric model. Rev. méd. Chile [online]. 2012, vol.140, n.1, pp.39-44. ISSN 0034-9887.  http://dx.doi.org/10.4067/S0034-98872012000100005.

Background: Cardiac output (CO) measurement is not a standard of care for critically ill children, but it can be estimated by indirect methods such as veno-arterial pCO2 difference (ΔVACO2). Aim: To determine the correlation between CO and ΔVACO2 and evaluate the usefulness of ΔVACO2 in the diagnosis of low CO in an experimental pediatric model. Materials and Methods: Thirty piglets weighing 4.8 ± 0.35 kg were anesthetized and monitored with transpulmonary thermodilution. Lung injury was induced with tracheal instillation of Tween 20®. Serial measurements of central venous and arterial blood gases, as well as CO, were obtained at baseline, 1, 2 and 4 h after lung injury induction. Low cardiac output (LCO) was defined as CO lower than 2.5 Llminlm2. Results: There was an inverse correlation between CO and ΔVACO2 (r = -0.36, p < 0.01). ΔVACO2 was 14 ± 8 mmHg in LCO state and 8 ± 6 mmHg when this condition was not present (p < 0.01). Area under the receiver operating characteristic (ROC) curves of ΔVACO2 and LCO state was 0.78 (0.68-0.86). The best cut-point was 8.9 mmHg to determine LCO with a sensibility 0.78, specificity 0.7, positive predictive value 0.27 and negative predictive value 0.96. Conclusions: In this model there was an inverse correlation between ΔVACO2 and CO. The best cutoff value to discard LCO was ΔVACO2 of 8.9 mmHg, indicating that under this value the presence of LCO is very unlikely.

Palabras clave : Blood gas monitoring; Carbon Dioxide; Critical Care; Hemodynamics; Cardiac Output.

        · texto en Español     · Español ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons