SciELO - Scientific Electronic Library Online

 
vol.134 número11Sensibilidad insulínica en niños de 6 a 15 años: asociación con estado nutricional y pubertadSíndrome de McLeod: compromiso multisistémico asociado a neuroacantocitosis ligada al cromosoma X, en una familia chilena índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

Compartir


Revista médica de Chile

versión impresa ISSN 0034-9887

Resumen

FRANGINI S, Patricia et al. Comparison of three brands of intracardiac pacemarker leads. Rev. méd. Chile [online]. 2006, vol.134, n.11, pp.1427-1435. ISSN 0034-9887.  http://dx.doi.org/10.4067/S0034-98872006001100010.

Background: Electrode lead design and materials influence their performance, stability and manipulation characteristics. In our laboratory, we use straight intracardiac, active fixation, steroid eluting leads. These features are shared by three brands of pacemarker distributors. Aim: To compare the short term results of three brands of leads used in our laboratory in patients requiring the implant of a pacemarker of cardioverter. Material and methods: One hundred and four patients (mean age 70 years, 59 males) subjected to a pacemarker or cardioverter implant were studied and followed during the first three months post implant. In these patients, 49 Guidant Flextend® 4087 or 4088, 27 Saint Jude Tendril® 1488T and 10 Medtronic Capsurefix® 5076 leads were implanted in the right atrium and 60 Guidant Flextend® 4087 or 4088, 29 Saint Jude Tendril® 1488T and 19 Medtronic Capsurefix® 5076 leads were implanted in the right ventricle. Results: Implant parameters were adequate for all leads. A sub-acute rise in ventricular stimulation threshold was detected in one Flextrend® lead. Three atrial leads (two Flextend® and one Capsurefix®) and one Capsurefix® ventricular lead experienced an acute displacement. One patient with a Flextend® lead, had a cardiac tamponade caused by an atrial perforation. Conclusions: The three brands of leads tested can be successfully implanted with comparable parameters and without differences in the evolution of patients during the first three months

Palabras clave : Cardiac pacemaker, artificial; Defibrillators, implantable; Heart block.

        · texto en Español     · Español ( pdf )

 