ZALAQUETT S, Ricardo et al. Valve repair surgery for incompetent bicuspid aortic valves. Rev. méd. Chile [online]. 2005, vol.133, n.3, pp.279-286. ISSN 0034-9887.  http://dx.doi.org/10.4067/S0034-98872005000300002.

Background: Surgical valve repair is a good alternative for correction of incompetent bicuspid aortic valve. Aim: To report the early and late surgical, clinical and ecochardiographic results of surgical repair of incompetent bicuspid aortic valves. Patients and methods: Retrospective review of medical records of 18 patients aged 19 to 61 years, with incompetent bicuspid aortic valve in whom a valve repair was performed. Four patients had infectious endocarditis and 17 were in functional class I or II. Follow up ranged from 3 to 113 months after surgery. Results: A triangular resection of the prolapsing larger cusp, which included the middle raphe, was performed in 17 cases; in 13 of these, a complementary subcommisural annuloplasty was performed. In the remaining case, with a perforation of the non-coronary cusp, a pericardial patch was implanted; this procedure was also performed in 2 other cases. In 3 cases large vegetations were removed. Postoperative transesophageal echocardiography showed no regurgitation in 11 patients (62%) and mild regurgitation in 7 (38%). There was no operative morbidity or mortality. There were no deaths during the follow-up period. In 3 patients (17%) the aortic valve was replaced with a mechanical prosthesis, 8 to 108 months after the first operation. Reoperation was not needed in 93%±6,4% at 1 year and 85%±9,5% at 5 years, these patients were all in functional class I at the end of the follow-up period. 60% had no aortic regurgitation, 20% had mild and 20% moderate aortic regurgitation on echocardiographic examination. A significant reduction of the diastolic diameter of the left ventricle was observed, but there were no significant changes in systolic diameter or shortening fraction. Conclusions: Surgical repair of incompetent bicuspid aortic valves has low operative morbidity and mortality and has a low risk of reoperation (Rev Méd Chile 2005; 133: 279-86)

Palavras-chave : Aortic valve; Cardiovascular surgical procedures; Heart valve prosthesis implantation.

        · texto em Espanhol     · Espanhol ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons