<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0718-381X</journal-id>
<journal-title><![CDATA[International journal of odontostomatology]]></journal-title>
<abbrev-journal-title><![CDATA[Int. J. Odontostomat.]]></abbrev-journal-title>
<issn>0718-381X</issn>
<publisher>
<publisher-name><![CDATA[Universidad de La Frontera. Facultad de Medicina]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0718-381X2012000100013</article-id>
<article-id pub-id-type="doi">10.4067/S0718-381X2012000100013</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Instrumentación Rotatoria en Endodoncia: Reporte de Casos Clínicos]]></article-title>
<article-title xml:lang="en"><![CDATA[Rotary Instrumentation in Endodontics: Clinical Cases Report]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Jiménez Ortiz]]></surname>
<given-names><![CDATA[José Leonardo]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Del Río Cazares]]></surname>
<given-names><![CDATA[Teresita Marisol]]></given-names>
</name>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad de Montemorelos Facultad de Ciencias de la Salud Escuela de Odontología]]></institution>
<addr-line><![CDATA[Montemorelos Nuevo León ]]></addr-line>
<country>México</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>04</month>
<year>2012</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>04</month>
<year>2012</year>
</pub-date>
<volume>6</volume>
<numero>1</numero>
<fpage>89</fpage>
<lpage>95</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.cl/scielo.php?script=sci_arttext&amp;pid=S0718-381X2012000100013&amp;lng=en&amp;nrm=iso&amp;tlng=en"></self-uri><self-uri xlink:href="http://www.scielo.cl/scielo.php?script=sci_abstract&amp;pid=S0718-381X2012000100013&amp;lng=en&amp;nrm=iso&amp;tlng=en"></self-uri><self-uri xlink:href="http://www.scielo.cl/scielo.php?script=sci_pdf&amp;pid=S0718-381X2012000100013&amp;lng=en&amp;nrm=iso&amp;tlng=en"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Los recientes avances en endodoncia de los últimos años, como la introducción de instrumentación rotatoria con limas de Niquel Titanio (NiTi), han simplificado el proceso del tratamiento, mejorando el éxito a largo plazo en términos de tiempo, efectividad y reducción de riesgos, comparados con la instrumentación manual con limas de acero inoxidable. Sin embargo, para algunos clínicos resulta difícil seleccionar el sistema rotatorio NiTi más apropiado, debido a la numerosa cantidad de instrumentos que conforman los diferentes sistemas existentes en el mercado. El presente reporte, basado en casos clínicos de la práctica diaria, tiene como objetivo mostrar, analizar y destacar la posibilidad de realizar tratamientos endodónticos predecibles con la técnica corono apical utilizando el sistema ProTaper Universal.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Advances in recent years in endodontics, such introduction of rotary Niquel Titanium (NiTi) instrumentation have simplified the treatment process and improved the long term success in terms of procedural time, accuracy, and risk reduction compared with the previously used, manual, stainless steel files. However, selecting the most appropriate NiTi system remains difficult for clinicians because of the large number of NiTi rotary instruments available nowadays on the market. This paper aims to show, analyze and emphasize, on the basis of every day clinical practice, the possibility of realizing predictability root canal preparations with the crown down technique of ProTaper Universal system.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[endodoncia]]></kwd>
<kwd lng="es"><![CDATA[instrumentación rotatoria]]></kwd>
<kwd lng="es"><![CDATA[técnica corono apical]]></kwd>
<kwd lng="es"><![CDATA[ProTaper Universal]]></kwd>
<kwd lng="en"><![CDATA[root canal treatment]]></kwd>
<kwd lng="en"><![CDATA[rotary instrumentation]]></kwd>
<kwd lng="en"><![CDATA[crown-down technique]]></kwd>
<kwd lng="en"><![CDATA[Protaper Universal]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  	     <p align="justify"><font face="verdana" size="2">Int. J. Odontostomat., 6(1):89&#45;95,    2012.</font></p>     <p align="justify">&nbsp;</p>  	     <p align="justify"><font face="verdana" size="4"><strong>Instrumentaci&oacute;n    Rotatoria en Endodoncia: Reporte de Casos Cl&iacute;nicos</strong></font></p>     <p align="justify">&nbsp;</p>  	     <p align="justify"><font face="verdana" size="3"><strong>Rotary Instrumentation    in Endodontics: Clinical Cases Report</strong></font></p>     <p align="justify">&nbsp;</p>  	     <p align="justify"><font face="verdana" size="2"><strong>Jos&eacute; Leonardo    Jim&eacute;nez Ortiz* &amp; Teresita Marisol Del R&iacute;o Cazares**</strong></font></p>     <p align="justify"><font face="verdana" size="2">* Cirujano Dentista Especialista    en Endodoncia, Jefe de Investigaci&oacute;n, Escuela de Odontolog&iacute;a,    Facultad de Ciencias de la Salud, Universidad de Montemorelos, Montemorelos    Nuevo Le&oacute;n, M&eacute;xico.    <br>   ** Cirujano Dentista Especialista en Endodoncia, Pr&aacute;ctica privada en    Piedras Negras, Coahuila, M&eacute;xico.</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><a name="top"></a><a href="#back">Direcci&oacute;n para correspondencia:</a></font></p> <hr width="100%" size="1">     <p align="justify"><font face="verdana" size="2"><strong>RESUMEN</strong>: Los    recientes avances en endodoncia de los &uacute;ltimos a&ntilde;os, como la introducci&oacute;n    de instrumentaci&oacute;n rotatoria con limas de Niquel Titanio (NiTi), han    simplificado el proceso del tratamiento, mejorando el &eacute;xito a largo plazo    en t&eacute;rminos de tiempo, efectividad y reducci&oacute;n de riesgos, comparados    con la instrumentaci&oacute;n manual con limas de acero inoxidable. Sin embargo,    para algunos cl&iacute;nicos resulta dif&iacute;cil seleccionar el sistema rotatorio    NiTi m&aacute;s apropiado, debido a la numerosa cantidad de instrumentos que    conforman los diferentes sistemas existentes en el mercado. El presente reporte,    basado en casos cl&iacute;nicos de la pr&aacute;ctica diaria, tiene como objetivo    mostrar, analizar y destacar la posibilidad de realizar tratamientos endod&oacute;nticos    predecibles con la t&eacute;cnica corono apical utilizando el sistema ProTaper    Universal.</font></p>  	     <p align="justify"><font face="verdana" size="2"><strong>PALABRAS CLAVE: endodoncia,    instrumentaci&oacute;n rotatoria, t&eacute;cnica corono apical, ProTaper Universal.</strong></font></p> <hr width="100%" size="1">     <p align="justify"><font face="verdana" size="2"><strong>ABSTRACT</strong>: Advances    in recent years in endodontics, such introduction of rotary Niquel Titanium    (NiTi) instrumentation have simplified the treatment process and improved the    long term success in terms of procedural time, accuracy, and risk reduction    compared with the previously used, manual, stainless steel files. However, selecting    the most appropriate NiTi system remains difficult for clinicians because of    the large number of NiTi rotary instruments available nowadays on the market.    This paper aims to show, analyze and emphasize, on the basis of every day clinical    practice, the possibility of realizing predictability root canal preparations    with the crown down technique of ProTaper Universal system.</font></p>     <p align="justify"><font face="verdana" size="2"><strong>KEY WORDS: root canal    treatment, rotary instrumentation, crown&#45;down technique, Protaper Universal.</strong></font></p> <hr width="100%" size="1">     <p align="justify"><font face="verdana" size="3"><strong>INTRODUCCI&Oacute;N</strong></font></p>  	    <p align="justify"><font face="verdana" size="2">El principal objetivo del tratamiento de canales es la limpieza mec&aacute;nica y qu&iacute;mica de la cavidad pulpar y su obturaci&oacute;n tridimensional con un material de sellado inerte y un sellado coronal que prevenga el ingreso de microorganismos (Schilder, 1974).</font></p>  	    <p align="justify"><font face="verdana" size="2">Los avances cient&iacute;ficos de los &uacute;ltimos a&ntilde;os, han permitido lograr este objetivo de manera m&aacute;s eficiente, mejorado as&iacute; el &eacute;xito a largo plazo del tratamiento endod&oacute;ntico. El uso de limas rotatorias de n&iacute;quel titanio (NiTi) durante la instrumentaci&oacute;n, ha ganado popularidad tanto en los endodoncistas como en los dentistas de practica general, debido a su mayor flexibilidad (Walia et al., 1988; Parashos &amp; Messer 2006) y capacidad de mantener la configuraci&oacute;n original de los canales curvos con paredes delgadas (Aguiar et al., 2009). Adem&aacute;s, existe evidencia de que estos sistemas reducen las fallas relacionadas con la instrumentaci&oacute;n y permiten una conformaci&oacute;n de conicidad adecuada con gran velocidad y efectividad (Guelzow et al., 2005; Moore et al., 2009). A pesar de presentar estas ventajas en comparaci&oacute;n con la instrumentaci&oacute;n manual realizada con limas de acero inoxidable, para algunos cl&iacute;nicos resulta dif&iacute;cil seleccionar el sistema rotatorio de limas NiTi m&aacute;s apropiado, debido a la numerosa cantidad de instrumentos que conforman los diferentes sistemas existentes en el mercado.</font></p>  	    <p align="justify"><font face="verdana" size="2">El sistema Protaper Universal (Dentsply Maillefer, Baillegues, Suiza) presenta en el dise&ntilde;o de sus instrumentos, una secci&oacute;n transversal triangular convexa, con una punta no cortante. Consta de seis limas, tres de conformaci&oacute;n: SX, S1 y S2; y tres limas de acabado: F1, F2, F3, adem&aacute;s de otras dos limas accesorias de acabado: F4 y F5. De acuerdo con las instrucciones del fabricante, la lima SX se utiliza para conformar la porci&oacute;n coronal, la lima S1 se emplea inicialmente 4 mm menos de la LT establecida, mientras que la S1 y S2 se llevan a LT para ensanchar progresivamente el tercio apical. Las limas F1, F2 y F3, son utilizadas para completar la terminaci&oacute;n apical. Las limas F4 y F5 se usan solamente si el caso lo requiere (West, 2006).</font></p>  	     <p align="justify"><font face="verdana" size="2">El objetivo de este reporte es    presentar y analizar casos cl&iacute;nicos de la pr&aacute;ctica diaria, para    eviden</font><font face="verdana" size="2">ciar la eficacia en el tratamiento    endod&oacute;ntico de &oacute;rganos dentales posteriores mandibulares y maxilares,    utilizando la t&eacute;cnica corono apical con los instrumentos rotatorios NiTi    ProTaper Universal.</font></p>  	     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><strong>REPORTE DE CASOS</strong></font></p>  	    <p align="justify"><font face="verdana" size="2">Se presentan cuatro casos cl&iacute;nicos atendidos endod&oacute;nticamente por los autores, los cuales fueron instrumentados y obturados en una sola sesi&oacute;n, utilizando el sistema ProTaper Universal. En cada uno de los casos, previa anestesia local, se procedi&oacute; al aislamiento absoluto con dique de hule para llevar a cabo el acceso coronal adecuado. Con la ayuda de lupas Surgitel (General Scientific Corporation, USA) con magnificaci&oacute;n 3.0 X, se localizaron cada uno de los orificios de entrada de los canales radiculares, y se procedi&oacute; a establecer la longitud de trabajo (LT) en cada uno de los canales de los diferentes &oacute;rganos dentales, utilizando el localizador de foramen apical Root ZX (J. Morita Inc, USA). Todos los canales se conformaron con la t&eacute;cnica corono apical con el sistema de instrumentaci&oacute;n rotatoria ProTaper Universal (Dentsply Maillefer, Baillegues, Suiza) de acuerdo a las instrucciones del fabricante: limas SX, S1 y S2 para la conformaci&oacute;n del tercio coronal y medio, y limas F1, F2 y F3 para la preparaci&oacute;n del tercio apical. Se permeabiliz&oacute; en los todos canales previamente instrumentados, con lima tipo K No. 10 (Dentsply Maillefer, Baillegues, Suiza).</font></p>  	     <p align="justify"><font face="verdana" size="2">Durante la preparaci&oacute;n    biomec&aacute;nica, se irrig&oacute; abundantemente con hipoclorito de sodio    al 2.5 %, EDTA al 17% (Vista Dental Products, USA) y soluci&oacute;n salina    al final, realizando activaci&oacute;n s&oacute;nica con el sistema Endoactivator    (Tulsa Dental Specialties, USA) de acuerdo a las instrucciones del fabricante,    al introducir con movimientos verticales en cada canal, una punta amarilla 20/.04,    roja 25/.04, o azul 30/.04 dependiendo del calibre antes instrumentado. Esto    se llev&oacute; a cabo 3 mm cortos de la LT establecida, en velocidad media    durante 30 segundos. Se procedi&oacute; al secado de los canales con puntas    de papel est&eacute;ril. La obturaci&oacute;n se realiz&oacute; con la t&eacute;cnica    de cono &uacute;nico, empleando gutapercha ProTaper Universal F1, F2 o F3 (Dentsply    Maillefer, Baillegues, Suiza) seg&uacute;n el calibre de la &uacute;ltima lima    utilizada durante la instrumentaci&oacute;n de los canales en cada uno de los    casos, utilizando cemento sellador Sealapex (SybronEndo, USA). La cavidad de    acceso se sell&oacute; con Provisit (Casa Idea, M&eacute;xico) y los pacientes    fueron remitidos a sus respectivos dentistas tratantes para la restauraci&oacute;n    prot&eacute;sica definitiva.</font></p>     <p align="justify"><font face="verdana" size="2"> <strong>CASO 1</strong></font></p>  	     <p align="justify"><font face="verdana" size="2">Paciente femenino de 28 a&ntilde;os    de edad, sintom&aacute;tico que acude a consulta endod&oacute;ntica de urgencia    por el primer molar inferior izquierdo (3.6). Sin datos importantes en su historia    m&eacute;dica, al interrogatorio refiri&oacute; sentir dolor con evoluci&oacute;n    de una semana. A la exploraci&oacute;n se observ&oacute; presencia de tejido    dental reblandecido en la superficie oclusal. No exist&iacute;a evidencia de    inflamaci&oacute;n de tejidos blandos o movilidad dental. Radiogr&aacute;ficamente,    se pudo apreciar una zona radiol&uacute;cida a nivel coronal, con proximidad    al cuerno distal de la c&aacute;mara pulpar, con ligero ensanchamiento de ligamento    periodontal, as&iacute; como dos ra&iacute;ces sin obstrucci&oacute;n aparente    en sus canales radiculares (<a href="#f1">Fig. 1</a>). Basados en los hallazgos    subjetivos y objetivos, se estableci&oacute; el diagn&oacute;stico de </font><font face="verdana" size="2">Pulpitis    Irreversible del diente 3.6, y se procedi&oacute; a realizar la terapia endod&oacute;ntica    con el Sistema ProTaper Universal de la manera descrita anteriormente, localizando    cuatro canales, dos en la ra&iacute;z mesial: el mesiovestibualr y mesiolingual;    dos canales m&aacute;s en la ra&iacute;z distal: el distovestibualr y distolingual    (<a href="#f2">Fig. 2</a>), instrumentando hasta el calibre F2 en los cuatro    canales (<a href="#f3">Fig. 3</a>), realizando la obturaci&oacute;n con gutapercha    del mismo calibre (<a href="#f4">Figs. 4</a> y <a href="#f5">5</a>).<a name="f1"></a></font></p>     <p align="center"><img src="/fbpe/img/ijodontos/v6n1/art13_f1.jpg" width="473" height="364"></p>     
<p align="center"><font size="2" face="verdana"><a name="f2"></a></font></p>     <p align="center"><font size="2" face="verdana"><img src="/fbpe/img/ijodontos/v6n1/art13_f2.jpg" width="472" height="357"></font></p>     
<p align="center"><font size="2" face="verdana"><a name="f3"></a></font></p>     <p align="center"><img src="/fbpe/img/ijodontos/v6n1/art13_f3.jpg" width="469" height="363"></p>     
]]></body>
<body><![CDATA[<p align="center"><font size="2" face="verdana"><a name="f4"></a></font></p>     <p align="center"><font size="2" face="verdana"><img src="/fbpe/img/ijodontos/v6n1/art13_f4.jpg" width="470" height="365"></font></p>     
<p align="center"><font size="2" face="verdana"><a name="f5"></a></font></p>     <p align="center"><font size="2" face="verdana"><img src="/fbpe/img/ijodontos/v6n1/art13_f5.jpg" width="459" height="351"></font></p>  	     
<p align="justify"><font face="verdana" size="2"><strong>CASO 2</strong></font></p>  	     <p align="justify"><font face="verdana" size="2">Paciente masculino de 52 a&ntilde;os    de edad, referido para recibir tratamiento endod&oacute;ntico, en el tercer    molar inferior izquierdo (3.8). Sin datos importantes en su historia m&eacute;dica,    asintom&aacute;tico, no present&oacute; respuesta a los est&iacute;mulos t&eacute;rmicos.    Al interrogatorio refiri&oacute; haber sido enviado por su dentista por motivos    prot&eacute;sicos. A la exploraci&oacute;n se observ&oacute; la presencia de    obturaci&oacute;n defectuosa con amalgama en la superficie oclusal. No exist&iacute;a    evidencia de inflamaci&oacute;n de tejidos blandos o movilidad dental. Radiogr&aacute;ficamente    se pudo apreciar, inclinaci&oacute;n mesial del &oacute;rgano dental a tratar,    una zona radiopaca a nivel coronal, sin proximidad a la c&aacute;mara pulpar,    una sola ra&iacute;z sin obstrucci&oacute;n aparente en su canal radicular,    presentado una curvatura moderada en el tercio apical (<a href="#f6">Fig. 6</a>).    Se estableci&oacute; el diagn&oacute;stico de Pulpa Sana del diente 3.8, y se    procedi&oacute; realizar el tratamiento endod&oacute;ntico por motivos prot&eacute;sicos    con el Sistema ProTaper Universal, instrumentando hasta el calibre F3 el &uacute;nico    canal localizado, para realizar su posterior obturaci&oacute;n con gutapercha    del mismo calibre (<a href="#f7">Fig. 7</a>).<a name="f6"></a></font></p>     <p align="center"><font size="2" face="verdana"><img src="/fbpe/img/ijodontos/v6n1/art13_f6.jpg" width="467" height="320"></font></p>     
<p align="center"><font size="2" face="verdana"><a name="f7"></a></font></p>     <p align="center"><img src="/fbpe/img/ijodontos/v6n1/art13_f7.jpg" width="466" height="318"><font face="verdana" size="2">    
<br>   Fig. 7.Radiograf&iacute;a final de obturaci&oacute;n conservando y respetando    la configuraci&oacute;n anat&oacute;mica    ]]></body>
<body><![CDATA[<br>   original del conducto, con presencia de extrusi&oacute;n de cemento sellador    <br>   en la regi&oacute;n apical, verificando la patencia apical del conducto.</font></p>     <p align="justify"><font face="verdana" size="2"><strong>CASO 3</strong></font></p>  	     <p align="justify"><font face="verdana" size="2">Paciente masculino de 33 a&ntilde;os    de edad, se presenta asintom&aacute;tico para recibir valoraci&oacute;n endod&oacute;ntica    en el primer molar superior izquierdo (1.6). Sin datos importantes en su historia    m&eacute;dica, present&oacute; respuesta a los est&iacute;mulos t&eacute;rmicos.    Al interrogatorio no refiri&oacute; sentir dolor, solamente sensibilidad al    ingerir bebidas fr&iacute;as. A la exploraci&oacute;n se observ&oacute; una    cavidad pigmentada en la superficie oclusal. No exist&iacute;a evidencia de    inflamaci&oacute;n de tejidos blandos o movilidad dental. Radiogr&aacute;ficamente,    se pudo apreciar una zona radiol&uacute;cida a nivel coronal, con tres ra&iacute;ces    separadas sin obstrucci&oacute;n aparente en sus canales radiculares (<a href="#f8">Fig.    8</a>). Basados en los hallazgos subjetivos y objetivos, se estableci&oacute;    el diagn&oacute;stico de Pulpitis Irreversible del diente 1.6, y se procedi&oacute;    a realizar la terapia endod&oacute;ntica con el Sistema ProTaper Universal de    la manera descrita anteriormente, localizando cuatro canales, dos en la ra&iacute;z    mesiovestibular, uno en la ra&iacute;z distovestibular y otro m&aacute;s en    la ra&iacute;z palatina. Se instrument&oacute; el canal mesiovestibular hasta    el claibre F2, el cuarto canal hasta F1, el canal distovestibular hasta F2,    mientras que el canal palatino hasta, F2 (<a href="#f9">Fig. 9</a>), para llevar    a cabo la obturaci&oacute;n con gutapercha del mismo calibre (<a href="#f10">Fig.    10</a>).<a name="f8"></a></font></p>     <p align="center"><font size="2" face="verdana"><img src="/fbpe/img/ijodontos/v6n1/art13_f8.jpg" width="473" height="315"></font></p>     
<p align="center"><font size="2" face="verdana"><a name="f9"></a></font></p>     <p align="center"><img src="/fbpe/img/ijodontos/v6n1/art13_f9.jpg" width="472" height="312"></p>     
<p align="center"><font size="2" face="verdana"><a name="f10"></a></font></p>  	     <p align="center"><font face="verdana" size="2"><img src="/fbpe/img/ijodontos/v6n1/art13_f10.jpg" width="472" height="334">    
<br>   Fig. 10. Radiograf&iacute;a final con la obturaci&oacute;n de los cuatro conductos:    mesiovestibular,     ]]></body>
<body><![CDATA[<br>   cuarto conducto, distovestibular y palatino. Extrusi&oacute;n de cemento sellador    en la regi&oacute;n     <br>   apical en la ra&iacute;z mesial y palatina que verifica la patencia apical de    los conductos.</font></p>  	     <p align="justify"><font face="verdana" size="2"><strong>CASO 4</strong></font></p>  	     <p align="justify"><font face="verdana" size="2">Paciente femenino de 74 a&ntilde;os    de edad, referida por su dentista tratante a consulta endod&oacute;ntica del    primer premolar superior derecho (2.4). Sin datos im</font><font face="verdana" size="2">portantes    en su historia m&eacute;dica, present&oacute; respuesta a los est&iacute;mulos    t&eacute;rmicos. Al interrogatorio refiri&oacute; sentir sensibilidad marcada    al ingerir bebidas fr&iacute;as con evoluci&oacute;n de dos semanas, esto inmediatamente    despu&eacute;s de ser tratada prot&eacute;sicamente en ese diente. A la exploraci&oacute;n    se observ&oacute; la presencia de una corona de metal porcelana. No exist&iacute;a    evidencia de inflamaci&oacute;n de tejidos blandos o movilidad dental. Radiogr&aacute;ficamente    se pudo apreciar una zona radiopaca a nivel coronal con una &aacute;rea radiol&uacute;cida    de la zona mesial en interproximal, que evidenciaba la falta de sellado de la    pr&oacute;tesis. Se observ&oacute; tambi&eacute;n, la presencia dos ra&iacute;ces    separadas: una vestibular y otra palatina, con obstrucci&oacute;n evidente debido    a la calcificaci&oacute;n de sus canales radiculares, presentado una curvatura    moderada en el tercio apical de su ra&iacute;z vestibular (<a href="#f11">Fig.    11</a>). Una vez establecido el diagn&oacute;stico de Pulpitis Irreversible    del diente 2.4 y previa anestesia local, la corona fue removida para proceder    al aislamiento absoluto y localizaci&oacute;n inicial de los ca&#45;nales vestibular    y palatino con limas de acero inoxidable No. 6. Despu&eacute;s de haber logrado    explorar la trayectoria de los canales con esa lima, se procedi&oacute; a instrumentar    con limas de calibre peque&ntilde;o: No.8, No. 10 y No. 15, hasta lograr un    camino gu&iacute;a reproducible, para dar paso a la instrumentaci&oacute;n con    el Sistema ProTaper Universal de la manera descrita anteriormente hasta el calibre    F2 en ambos canales. La obturaci&oacute;n se llev&oacute; a cabo utilizando    gutapercha del mismo sistema y calibre (<a href="#f12">Fig. 12</a>).<a name="f11"></a></font></p>     <p align="center"><font size="2" face="verdana"><img src="/fbpe/img/ijodontos/v6n1/art13_f11.jpg" width="472" height="702"></font></p>     
<p align="center"><font size="2" face="verdana"><a name="f13"></a></font></p>     <p align="center"><font size="2" face="verdana"><img src="/fbpe/img/ijodontos/v6n1/art13_f12.jpg" width="469" height="697"></font></p>  	    
<p align="justify"><font face="verdana" size="2">    <br>   <strong><font size="3">DISCUSI&Oacute;N</font></strong></font></p>  	     <p align="justify"><font face="verdana" size="2">La instrumentaci&oacute;n rotatoria    con limas de n&iacute;quel titanio (NiTi), es un importante coadyuvante en la    terapia endod&oacute;ntica, ya que ha mejorado la pr&aacute;ctica cl&iacute;nica    en t&eacute;rminos de tiempo, efectividad y reducci&oacute;n de riesgos (Parashos    &amp; Messer) comparados con la instrumentaci&oacute;n manual con limas de ace</font><font face="verdana" size="2">ro    inoxidable. Resulta dif&iacute;cil para algunos cl&iacute;nicos seleccionar    el sistema rotatorio NiTi m&aacute;s adecuado a sus necesidades, debido a la    numerosa cantidad de instrumentos que conforman los diferentes sistemas que    actualmente se encuentran a la venta en el mercado endod&oacute;ntico, aunado    a la dificultad de familiarizarse con la secuencia de uso de los instrumentos    y a la gran inquietud existente respecto a la fractura de estos instrumentos.    Se ha publicado en la literatura de los &uacute;ltimos diez a&ntilde;os, reportes    de estudios que muestran hallazgos referentes a los diversos factores que influyen    en la fractura (Mart&iacute;n et al., 2003; Shen et al., 2009), resistencia    a la fatiga c&iacute;clica (Bahia et al., 2008; Fife et al., 2004), facilidad    de uso (Peru et al., 2006) y capacidad de configuraci&oacute;n los canales radiculares    (H&uuml;lsmann et al., 2003; Williamson et al., 2009) de los diferentes sistemas    de instrumentaci&oacute;n rotatoria NiTi. Existe evidencia que el sistema Protaper    Universal (Dentsply Maillefer, Baillegues, Suiza), el cual presenta en el dise&ntilde;o    de sus instrumentos NiTi una conicidad variable progresiva, con una secci&oacute;n    transversal triangular convexa y punta no cortante, mejora la acci&oacute;n    de corte, flexibilidad y eficiencia (Ozgur Uyanik et al., 2006), disminuye la    fricci&oacute;n rotacional entre la hoja de corte de la lima y dentina, minimizando    la fatiga del instrumento (Calberson et al., 2004). La separaci&oacute;n de    limas se presenta como un riesgo potencial cuando se utiliza cualquier sistema    de instrumentaci&oacute;n NiTi durante la conformaci&oacute;n de canales radiculares    en la terapia endod&oacute;ntica. La resistencia a la fatiga c&iacute;clica    de la limas NiTi del sistema ProTaper Universal (Dentsply Maillefer, Baillegues,    Suiza), ha sido examinada en estudios in vivo, despu&eacute;s de utilizarse    de manera inicial en canales rectos y curvos demostrando resultados favorables    (Ounsi et al., 2007). Se ha demostrado que el uso cl&iacute;nico prolongado    de los instrumentos rotatorios ProTaper (de 12 hasta 16 canales) redujo significativamente    su resistencia a la fatiga c&iacute;clica (Fife et al.). Reportes indican que    las limas ProTaper pueden ser utilizadas de forma segura por lo menos hasta    cuatro veces (Wolcott et al., 2006). Estudios realizados sugieren que el sistema    ProTaper presenta una mayor capacidad de crear una preparaci&oacute;n m&aacute;s    regular (Guelzow et al.), produciendo configuraciones centradas en canales radiculares    curvos y delgados con una baja proporci&oacute;n de desviaci&oacute;n apical    (Aguiar et al.), al ser comparados con otros sistemas de instrumentaci&oacute;n.    Existe evidencia de que una vez terminada la preparaci&oacute;n mec&aacute;nica,    se debe complementar la limpieza de los canales radiculares mediante el uso    de las diferentes t&eacute;cnicas de activaci&oacute;n de la soluci&oacute;n    irrigante (Gu et al., 2009). El sistema EndoActivator (Dentsply Tulsa Dental    Specialties, USA) de reciente introducci&oacute;n como coadyuvante durante la    terapia endod&oacute;ntica, consiste en una pieza de mano inal&aacute;mbrica    que utiliza tres puntas desechables de pol&iacute;mero flexible con diferentes    calibres no cortantes, dise&ntilde;adas para la activaci&oacute;n s&oacute;nica    de los agentes irrigantes dentro del sistema de canales radiculares, produciendo    una agitaci&oacute;n vigorosa de flu&iacute;dos (Ruddle, 2008). Este sistema    ha demostrado proporcionar una mejor irrigaci&oacute;n en canales laterales    simulados a 4,5 y 2 mm de la longitud de trabajo, comparado con el solo uso    tradicional de irrigaci&oacute;n con jeringa (de Gregorio et al., 2009), as&iacute;    como la remoci&oacute;n del lodo dentinario con agentes desmineralizantes como    el EDTA y pel&iacute;culas de biofilm en canales radiculares curvos (Caron et    al., 2010).</font></p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">En conclusi&oacute;n, el presente reporte de &oacute;rganos dentales posteriores mandibulares y maxilares evidencia la eficacia cl&iacute;nica de una pr&aacute;ctica endod&oacute;ntica predecible, utilizando la t&eacute;cnica corono apical con los instrumentos rotatorios NiTi ProTaper Universal.</font></p>  	     <p align="justify">&nbsp;</p>  	     <p align="justify"><font face="verdana" size="3"><strong>REFERENCIAS BIBLIOGR&Aacute;FICAS</strong></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">Aguiar, C. M.; de Andrade Mendes, D.; C&acirc;mara, A. C. &amp; de Figueiredo, J. A. Evaluation of the centering ability of the ProTaper Universal rotary system in curved roots in comparison to Nitiflex files. Aust. Endod. J., 35(3):174&#45;9, 2009.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scieloOrg/php/reflinks.php?refpid=S0718-381X201200010001300001&pid=S0718-381X2012000100013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');"></a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">Bahia, M. G.; Melo, M. C. &amp; Buono, V. T. Influence of cyclic torsional loading on the fatigue resistance of K3 instruments. Int. Endod. J., 41(10):883&#45;91, 2008.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scieloOrg/php/reflinks.php?refpid=S0718-381X201200010001300002&pid=S0718-381X2012000100013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');"></a>&#160;]<!-- end-ref --></font></p>  	     <!-- ref --><p align="justify"><font face="verdana" size="2">Calberson, F. L.; Deroose, C.    A.; Hommez, G. M. &amp; De Moor, R. J. Shaping ability of ProTaper nickel titanium    ?les in simulated resin root canals. Int. Endod. J., 37(9):613&#45;23, 2004.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scieloOrg/php/reflinks.php?refpid=S0718-381X201200010001300003&pid=S0718-381X2012000100013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');"></a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">Caron, G.; Nham, K.; Bronnec, F. &amp; Machtou, P. Effectiveness of different final irrigant activation protocols on smear layer removal in curved canals. J. Endod., 36(8):1361&#45;6, 2010.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scieloOrg/php/reflinks.php?refpid=S0718-381X201200010001300004&pid=S0718-381X2012000100013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');"></a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">de Gregorio, C.; Estevez, R.; Cisneros, R.; Heilborn, C. &amp; Cohenca, N. Effect of EDTA, sonic, and ultrasonic activation on the penetration of sodium hypochlorite into simulated lateral canals: an in vitro study. J. Endod., 35(6):891&#45;5, 2009.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scieloOrg/php/reflinks.php?refpid=S0718-381X201200010001300005&pid=S0718-381X2012000100013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');"></a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">Fife, D.; Gambarini, G. &amp; Britto, L. R. Cyclic fatigue testing of ProTaper NiTi rotary instruments after clinical use. Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endod., 97(2):251&#45;6, 2004.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scieloOrg/php/reflinks.php?refpid=S0718-381X201200010001300006&pid=S0718-381X2012000100013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');"></a>&#160;]<!-- end-ref --></font></p>  	     <!-- ref --><p align="justify"><font face="verdana" size="2">Gu, L. S.; Kim, J. R.; Ling,    J.; Choi, K. K.; Pashley, D. H. &amp; Tay, F. R. Review of contemporary irrigant    agitation techniques and devices. J. Endod., 35(6):791&#45;804, 2009.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scieloOrg/php/reflinks.php?refpid=S0718-381X201200010001300007&pid=S0718-381X2012000100013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');"></a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">Guelzow, A.; Stamm, O.; Martus, P. &amp; Kielbassa, A. M. Comparative study of six rotary nickel&#45;titanium systems and hand instrumentation for root canal preparation. Int. Endod. J., 38(10):743&#45;52, 2005.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scieloOrg/php/reflinks.php?refpid=S0718-381X201200010001300008&pid=S0718-381X2012000100013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');"></a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">H&uuml;lsmann, M.; Herbst, U. &amp; Sch&auml;fers, F. Comparative study of root&#45;canal preparation using Lightspeed and Quantec SC rotary NiTi instruments. Int. Endod. J., 36(11):748&#45;56, 2003.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scieloOrg/php/reflinks.php?refpid=S0718-381X201200010001300009&pid=S0718-381X2012000100013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');"></a>&#160;]<!-- end-ref --></font></p>  	     <!-- ref --><p align="justify"><font face="verdana" size="2">Mart&iacute;n, B.; Zelada, G.;    Varela, P.; Bahillo, J. G.; Mag&aacute;n, F.; Ahn, S. &amp; Rodr&iacute;guez,    C. Factors influencing the fracture of nickeltitanium rotary instruments. Int.    Endod. J., 36(4):262&#45;6, 2003.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scieloOrg/php/reflinks.php?refpid=S0718-381X201200010001300010&pid=S0718-381X2012000100013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');"></a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">Moore, J.; Fitz&#45;Walter, P. &amp; Parashos, P. A micro&#45;computed tomographic evaluation of apical root canal preparation using three instrumentation techniques. Int. Endod. J., 42(12):1057&#45;64, 2009.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scieloOrg/php/reflinks.php?refpid=S0718-381X201200010001300011&pid=S0718-381X2012000100013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');"></a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">Ounsi, H. F.; Salameh, Z.; Al&#45;Shalan, T.; Ferrari, M.; Grandini, S.; Pashley, D. H. &amp; Tay, F. R. Effect of clinical use on the cyclic fatigue resistance of ProTaper nickel&#45;titanium rotary instruments. J. Endod., 33(6):737&#45;41, 2007.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scieloOrg/php/reflinks.php?refpid=S0718-381X201200010001300012&pid=S0718-381X2012000100013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');"></a>&#160;]<!-- end-ref --></font></p>  	     <!-- ref --><p align="justify"><font face="verdana" size="2">Ozgur Uyanik, M.; Cehreli, Z.    C.; Ozgen Mocan, B. &amp; Tasman Dagli, F. Comparative evaluation of three Nickel&#45;titanium    instrumentation systems in human teeth using computed tomography. J. Endod.,    32(7):668&#45;71, 2006.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scieloOrg/php/reflinks.php?refpid=S0718-381X201200010001300013&pid=S0718-381X2012000100013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');"></a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2"> Parashos, P. &amp; Messer, H.    H. The diffusion of innovation in dentistry: a review using rotary nickel&#45;titanium    technology as an example. Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endod.,    101(3):395&#45;401, 2006.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scieloOrg/php/reflinks.php?refpid=S0718-381X201200010001300014&pid=S0718-381X2012000100013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');"></a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">Peru, M.; Peru, C.; Mannocci, F.; Sherriff, M.; Buchanan, L. S. &amp; Pitt Ford, T. R. Hand and nickel&#45;titanium root canal instrumentation performed by dental students: a microcomputed tomographic study. Eur. J. Dent. Educ., 10(1):529, 2006.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scieloOrg/php/reflinks.php?refpid=S0718-381X201200010001300015&pid=S0718-381X2012000100013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');"></a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">Ruddle, C. J. Endodontic disinfection: tsunami irrigation. Endod. Practice, 11:7&#45;15, 2008.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scieloOrg/php/reflinks.php?refpid=S0718-381X201200010001300016&pid=S0718-381X2012000100013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');"></a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">Schilder, H. Cleaning and shaping the root canal. Dent. Clin. North Am., 18(2):269&#45;96, 1974.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scieloOrg/php/reflinks.php?refpid=S0718-381X201200010001300017&pid=S0718-381X2012000100013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');"></a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">Shen, Y.; Coil, J. M.; McLean, A. G.; Hemerling, D. L. &amp; Haapasalo, M. Defects in nickel&#45;titanium instruments after clinical use, Part 5: single use from endodontic specialty practices. J. Endod., 35(10):1363&#45;7, 2009.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scieloOrg/php/reflinks.php?refpid=S0718-381X201200010001300018&pid=S0718-381X2012000100013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');"></a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">Walia, H. M.; Brantley, W. A. &amp; Gerstein, H. An initial investigation of the bending and torsional properties of nitinol root canal files. J. Endod., 14(7):346&#45;51, 1988.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scieloOrg/php/reflinks.php?refpid=S0718-381X201200010001300019&pid=S0718-381X2012000100013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');"></a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">West, J. Progressive taper technology: rationale and clinical technique for the new ProTaper universal system. Dent. Today, 25(12):64, 66&#45;9, 2006.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scieloOrg/php/reflinks.php?refpid=S0718-381X201200010001300020&pid=S0718-381X2012000100013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');"></a>&#160;]<!-- end-ref --></font></p>  	    <p align="justify"><font face="verdana" size="2">Williamson, A. E.; Sandor, A. J. &amp; Justman, B. C. A comparison of three nickel titanium rotary systems, EndoSequence, ProTaper universal, and profile GT, for canal&#45;cleaning ability.    <br> 	J. Endod., 35(1):107&#45;9, 2009.</font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">Wolcott, S.; Wolcott, J.; Ishley, D.; Kennedy, W.; Johnson, S.; Minnich, S. &amp; Meyers, J. Separation incidence of protaper rotary instruments: a large cohort clinical evaluation. J. Endod., 32(12):1139&#45;41, 2006.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scieloOrg/php/reflinks.php?refpid=S0718-381X201200010001300022&pid=S0718-381X2012000100013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');"></a>&#160;]<!-- end-ref --></font></p>  	 <hr align="left" width="30%" size="1">     <p align="justify"><font face="Verdana"><font size="2"><a name="back" id="back"></a><a href="#top"><img src="/fbpe/img/ijodontos/v6n1/flecha.gif" alt="" width="15" height="17" /></a></font></font><font face="verdana" size="2"></font><font face="verdana" size="2"></font><font face="verdana" size="2">Direcci&oacute;n para correspondencia:    </font></p>     
<p align="justify"><font face="verdana" size="2"><strong>Jos&eacute; Leonardo    Jim&eacute;nez Ortiz</strong></font></p>     <p align="justify"><font face="verdana" size="2"> Cirujano Dentista Especialista    en Endodoncia,    ]]></body>
<body><![CDATA[<br>    Jefe de Investigaci&oacute;n, Escuela de Odontologia    <br>   Facultad de Ciencias de la Salud    <br>   Universidad de Montemorelos    <br>   Libertad No. 1300 Col. Centro    <br>   Montemorelos Nuevo Le&oacute;n    <br>   C.P. 67530 M&Eacute;XICO    <br>   </font><font face="verdana" size="2">Tel&eacute;fonos: +52 (826) 263&#45;5824;    <br>   +52(826) 263&#45;5529</font></p>  	     <p align="justify"><font face="verdana" size="2">Email: <a href="mailto:endodoncia@um.edu.mx">endodoncia@um.edu.mx</a></font></p>  	    <p align="justify"><font face="verdana" size="2">Recibido : 22&#45;11&#45;2011</font></p>     ]]></body>
<body><![CDATA[ ]]></body><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Aguiar]]></surname>
<given-names><![CDATA[C. M.]]></given-names>
</name>
<name>
<surname><![CDATA[de Andrade Mendes]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Câmara]]></surname>
<given-names><![CDATA[A. C.]]></given-names>
</name>
<name>
<surname><![CDATA[de Figueiredo]]></surname>
<given-names><![CDATA[J. A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evaluation of the centering ability of the ProTaper Universal rotary system in curved roots in comparison to Nitiflex files.]]></article-title>
<source><![CDATA[Aust. Endod. J.]]></source>
<year>2009</year>
<volume>35</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>174-9</page-range></nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bahia]]></surname>
<given-names><![CDATA[M. G.]]></given-names>
</name>
<name>
<surname><![CDATA[Melo]]></surname>
<given-names><![CDATA[M. C.]]></given-names>
</name>
<name>
<surname><![CDATA[Buono]]></surname>
<given-names><![CDATA[V. T.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence of cyclic torsional loading on the fatigue resistance of K3 instruments]]></article-title>
<source><![CDATA[Int. Endod. J.]]></source>
<year>2008</year>
<volume>41</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>883-91</page-range></nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Calberson]]></surname>
<given-names><![CDATA[F. L.]]></given-names>
</name>
<name>
<surname><![CDATA[Deroose]]></surname>
<given-names><![CDATA[C. A.]]></given-names>
</name>
<name>
<surname><![CDATA[Hommez]]></surname>
<given-names><![CDATA[G. M.]]></given-names>
</name>
<name>
<surname><![CDATA[De Moor]]></surname>
<given-names><![CDATA[R. J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Shaping ability of ProTaper nickel titanium ?les in simulated resin root canals]]></article-title>
<source><![CDATA[Int. Endod. J.]]></source>
<year>2004</year>
<volume>37</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>613-23</page-range></nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Caron]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Nham]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Bronnec]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Machtou]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effectiveness of different final irrigant activation protocols on smear layer removal in curved canals]]></article-title>
<source><![CDATA[J. Endod.]]></source>
<year>2010</year>
<volume>36</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>1361-6</page-range></nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[de Gregorio]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Estevez]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Cisneros]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Heilborn]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Cohenca]]></surname>
<given-names><![CDATA[N.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of EDTA, sonic, and ultrasonic activation on the penetration of sodium hypochlorite into simulated lateral canals: an in vitro study]]></article-title>
<source><![CDATA[J. Endod.]]></source>
<year>2009</year>
<volume>35</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>891-5</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fife]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Gambarini]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Britto]]></surname>
<given-names><![CDATA[L. R.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cyclic fatigue testing of ProTaper NiTi rotary instruments after clinical use]]></article-title>
<source><![CDATA[Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endod.]]></source>
<year>2004</year>
<volume>97</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>251-6</page-range></nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gu]]></surname>
<given-names><![CDATA[L. S.]]></given-names>
</name>
<name>
<surname><![CDATA[Kim]]></surname>
<given-names><![CDATA[J. R.]]></given-names>
</name>
<name>
<surname><![CDATA[Ling]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Choi]]></surname>
<given-names><![CDATA[K. K.]]></given-names>
</name>
<name>
<surname><![CDATA[Pashley]]></surname>
<given-names><![CDATA[D. H.]]></given-names>
</name>
<name>
<surname><![CDATA[Tay]]></surname>
<given-names><![CDATA[F. R.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Review of contemporary irrigant agitation techniques and devices.]]></article-title>
<source><![CDATA[J. Endod.]]></source>
<year>2009</year>
<volume>35</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>791-804</page-range></nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Guelzow]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Stamm]]></surname>
<given-names><![CDATA[O.]]></given-names>
</name>
<name>
<surname><![CDATA[Martus]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Kielbassa]]></surname>
<given-names><![CDATA[A. M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparative study of six rotary nickel-titanium systems and hand instrumentation for root canal preparation.]]></article-title>
<source><![CDATA[Int. Endod. J.]]></source>
<year>2005</year>
<volume>38</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>743-52</page-range></nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hülsmann]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Herbst]]></surname>
<given-names><![CDATA[U.]]></given-names>
</name>
<name>
<surname><![CDATA[Schäfers]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparative study of root-canal preparation using Lightspeed and Quantec SC rotary NiTi instruments]]></article-title>
<source><![CDATA[Int. Endod. J.]]></source>
<year>2003</year>
<volume>36</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>748-56</page-range></nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Martín]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
<name>
<surname><![CDATA[Zelada]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Varela]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Bahillo]]></surname>
<given-names><![CDATA[J. G.]]></given-names>
</name>
<name>
<surname><![CDATA[Magán]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Ahn]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Rodríguez]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Factors influencing the fracture of nickeltitanium rotary instruments]]></article-title>
<source><![CDATA[Int. Endod. J.]]></source>
<year>2003</year>
<volume>36</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>262-6</page-range></nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Moore]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Fitz-Walter]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Parashos]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A micro-computed tomographic evaluation of apical root canal preparation using three instrumentation techniques]]></article-title>
<source><![CDATA[Int. Endod. J.]]></source>
<year>2009</year>
<volume>42</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>1057-64</page-range></nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ounsi]]></surname>
<given-names><![CDATA[H. F.]]></given-names>
</name>
<name>
<surname><![CDATA[Salameh]]></surname>
<given-names><![CDATA[Z.]]></given-names>
</name>
<name>
<surname><![CDATA[Al-Shalan]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Ferrari]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Grandini]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Pashley]]></surname>
<given-names><![CDATA[D. H.]]></given-names>
</name>
<name>
<surname><![CDATA[Tay]]></surname>
<given-names><![CDATA[F. R.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of clinical use on the cyclic fatigue resistance of ProTaper nickel-titanium rotary instruments.]]></article-title>
<source><![CDATA[J. Endod.]]></source>
<year>2007</year>
<volume>33</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>737-41</page-range></nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ozgur Uyanik]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Cehreli]]></surname>
<given-names><![CDATA[Z. C.]]></given-names>
</name>
<name>
<surname><![CDATA[Ozgen Mocan]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
<name>
<surname><![CDATA[Tasman Dagli]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparative evaluation of three Nickel-titanium instrumentation systems in human teeth using computed tomography]]></article-title>
<source><![CDATA[J. Endod.]]></source>
<year>2006</year>
<volume>32</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>668-71</page-range></nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Parashos]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Messer]]></surname>
<given-names><![CDATA[H. H.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The diffusion of innovation in dentistry: a review using rotary nickel-titanium technology as an example]]></article-title>
<source><![CDATA[Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endod.]]></source>
<year>2006</year>
<volume>101</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>395-401</page-range></nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Peru]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Peru]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Mannocci]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Sherriff]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Buchanan]]></surname>
<given-names><![CDATA[L. S.]]></given-names>
</name>
<name>
<surname><![CDATA[Pitt Ford]]></surname>
<given-names><![CDATA[T. R.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Hand and nickel-titanium root canal instrumentation performed by dental students: a microcomputed tomographic study]]></article-title>
<source><![CDATA[Eur. J. Dent. Educ.]]></source>
<year>2006</year>
<volume>10</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>529</page-range></nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ruddle]]></surname>
<given-names><![CDATA[C. J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Endodontic disinfection: tsunami irrigation]]></article-title>
<source><![CDATA[Endod. Practice]]></source>
<year>2008</year>
<volume>11</volume>
<page-range>7-15</page-range></nlm-citation>
</ref>
<ref id="B17">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schilder]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cleaning and shaping the root canal]]></article-title>
<source><![CDATA[Dent. Clin. North Am.]]></source>
<year>1974</year>
<volume>18</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>269-96</page-range></nlm-citation>
</ref>
<ref id="B18">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shen]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Coil]]></surname>
<given-names><![CDATA[J. M.]]></given-names>
</name>
<name>
<surname><![CDATA[McLean]]></surname>
<given-names><![CDATA[A. G.]]></given-names>
</name>
<name>
<surname><![CDATA[Hemerling]]></surname>
<given-names><![CDATA[D. L.]]></given-names>
</name>
<name>
<surname><![CDATA[Haapasalo]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Defects in nickel-titanium instruments after clinical use, Part 5: single use from endodontic specialty practices]]></article-title>
<source><![CDATA[J. Endod.]]></source>
<year>2009</year>
<volume>35</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>1363-7</page-range></nlm-citation>
</ref>
<ref id="B19">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Walia]]></surname>
<given-names><![CDATA[H. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Brantley]]></surname>
<given-names><![CDATA[W. A.]]></given-names>
</name>
<name>
<surname><![CDATA[Gerstein]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An initial investigation of the bending and torsional properties of nitinol root canal files]]></article-title>
<source><![CDATA[J. Endod.]]></source>
<year>1988</year>
<volume>14</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>346-51</page-range></nlm-citation>
</ref>
<ref id="B20">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[West]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Progressive taper technology: rationale and clinical technique for the new ProTaper universal system]]></article-title>
<source><![CDATA[Dent. Today]]></source>
<year>2006</year>
<volume>25</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>64, 66-9</page-range></nlm-citation>
</ref>
<ref id="B21">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Williamson]]></surname>
<given-names><![CDATA[A. E.]]></given-names>
</name>
<name>
<surname><![CDATA[Sandor]]></surname>
<given-names><![CDATA[A. J.]]></given-names>
</name>
<name>
<surname><![CDATA[Justman]]></surname>
<given-names><![CDATA[B. C.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A comparison of three nickel titanium rotary systems, EndoSequence, ProTaper universal, and profile GT, for canal-cleaning ability]]></article-title>
<source><![CDATA[J. Endod.]]></source>
<year>2009</year>
<volume>35</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>107-9</page-range></nlm-citation>
</ref>
<ref id="B22">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wolcott]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Wolcott]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Ishley]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Kennedy]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
<name>
<surname><![CDATA[Johnson]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Minnich]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Meyers]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Separation incidence of protaper rotary instruments: a large cohort clinical evaluation]]></article-title>
<source><![CDATA[J. Endod.]]></source>
<year>2006</year>
<volume>32</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>1139-41</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
