SciELO - Scientific Electronic Library Online

 
vol.55 número2PRODUCTION OF VOLATILE ORGANIC COMPOUNDS (VOCS) BY TEMPERATE MACROALGAE: THE USE OF SOLID PHASE MICROEXTRACTION (SPME) COUPLED TO GC-MS AS METHOD OF ANALYSISSYNTHESIS, SPECTRAL CHARACTERIZATION AND ELECTROCHEMISTRY OF VANADIUM(V) COMPLEX WITH TRYPTOPHAN índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Journal of the Chilean Chemical Society

versión On-line ISSN 0717-9707

J. Chil. Chem. Soc. v.55 n.2 Concepción jun. 2010

http://dx.doi.org/10.4067/S0717-97072010000200019 

J. Chil. Chem. Soc, 55, N° 2 (2010), págs.: 233-235

 

BIOSENSORS' PREPARATION TO BE USED FOR ENTRAPMENT METHOD WITH COPOLYMERS POLYANILINE DERIVATIVES

 

C. O. SANCHEZ1*, A. ISLA1, C. BUSTOS1, F. DÍAZ2, N. GATICA3

1. Instituto de Química, Facultad de Ciencias, Universidad Austral de Chile, Avda. Las Encinas 220, Isla Teja, Valdivia, Chile.
2. Departamento de Química Orgánica, Facultad de Química, Universidad Católica de Chile, Avda. Vicuña Mackenna 4860, Macul-Santiago, Chile
3. Departamento de Polímeros, Facultad de Ciencias, Universidad de Concepción, Edmundo Larenas 129, Concepción, Chile


ABSTRACT

The entrapment method was used to prepare electrochemical biosensors. Using controlled potential method, copolymers were synthesized between aniline y sulfonated-anilines in aqueous media at pH 4.9 on Platinum disc. The copolymers were characterized by elemental analysis and spectroscopy. Glucose-oxidase was entrapped in the electropolymerization process, at pH 4.9 in aqueous media. The copolymers modified electrodes and copolymer/enzyme were studied as working electrodes for the oxidation of different H2O2 concentrations and indirect D-glucose quantification at pH 7, using controlled potential and the cyclic voltammetry methods (CV) correspondingly. A linear relationship between the hydrogen peroxide (or D-glucose) concentration and the electrochemical response was obtained at pH 7. The modified-electrodes displayed a fast time of currentresponse, limitedbythe cyclenumbers of the cyclic voltammetry, 232 s, andenough stability to allow for the measurements to be taken after several days.

Keywords: Copolymers, Electrochemistry, enzyme, biosensor


INTRODUCTION

Polymers have been used in the preparation of biosensors, which can quantify the hydrogen peroxide generated in the oxidation of sugars, the reaction is catalyzed by oxidase-type enzymes1-3. The hydrogen peroxide formed in the reaction of oxidation can be quantified by electrochemical methods and its amount is directly related with the sugar quantity. The immovilized enzymes in polypirrol have been carried out by several methods such as physical adsorption, covalent unión, entrapment and electrochemical doping2-9. The entrapment method involves to capture the enzyme during the polymer electrosynthesis process, from a monomeric solution that contains the enzyme. This method presents the following requirements, the process of polymerization should be carried out in aqueous medium and pH that no deactivate or denature the enzyme, the monomer should be soluble in aqueous media and it's desirable that the polymer exhibits conductivity properties. Because to the previous requirements, polyaniline and polyaniline derivatives have not been studied enough using the entrapment method because: i) the monomer is practically insoluble at neutral pH in aqueous medium, ii) the polymer prepared at pH > 3.5, is non-conducting, and at pH < 3 the enzyme is de-naturalized9, iii) the polymer can be electrochemically synthesized in strong acid medium, nevertheless, the acid absorbed in the resulting polymer denatures the enzyme4,9,12-14. Therefore, the entrapment method using aniline as monomer can not be used. We solved this problem by preparing copolymers using aniline derivatives. The copolymers should be electroactive and insoluble at pH 5-7, it is desirable they be electrically conductive and the co-monomers should be soluble in an aqueous media in the range of pH 5-7. After an extensive review of published data, we postulated that the co-monomers of aniline derivatives 2-amino phenyl sulfonic acid and 3-amino phenyl sulfonic acid can be used to inmovilize enzymes in the polymerization process.

The goal of this paper is to prepare biosensors using the entrapment method with the copolymers between aniline and 2-amino phenyl sulfonic acid and 3-aminophenyl sulfonic acid. The enzyme (glucose-oxidase) entrapment was possible by the electropolymerization process in aqueous medium (pH 4.9) without denaturing the enzyme. The behavior of the obtained biosensors in relationship to electrochemical response of hydrogen peroxide and D-glucose in aqueous media at pH 7 are also reported.

To study the bio-electrodes, the electrodes Pt/copolymers and Platinum disc were analized as working electrodes for the oxidation of H2O2 solutions at different concentrations, using cyclic voltammetry and the controlled potential electrochemical method.

EXPERIMENTAL

Physical measurements

Potenciodynamic measurements, cyclic voltammetry and electropolymerizations were conducted with a Voltametric Analyzer Bioanalytical System Inc, model C-3, in three-electrode cells, using platinum disc (7.07 mm2) as working electrode, a Ag/AgCl as reference electrode, and a coil platinum wire (0.5 mm diameter) as an auxiliary electrode. Working electrodes were polished using aluminum oxide paste to obtain shiny surfaces prior to copolymer depositions. Sufficient amount of polymers were obtained to achieve the elemental analysis using 4-cm2 platinum sheets as working electrodes. Then, the films were removed from electrodes by solubilization with acetone and acetonitrile, and finally the solvent was eliminated under vacuum at 40-50°.

The copolymer's composition and the functional groups were determined by elemental analysis and FT-IR spectroscopy. Elemental analysis (C, H, N, S) was performed using an EA-1108, Fisons Elemental Analyzer. IR spectra were recorded on a Nicolet FT-IR Nexus spectrophotometer on KBr pellets. The UV-Vis spectra were recorded in solution using 0.03121 M triethylamine prepared in dimethylformamide (DMF) as dissolvent, in a 1-cm long cell at room temperature (20 °). The UV-Vis spectra were registered with a UNICAM UV 500 equipment.

Reagents

Reagent grade KH2PO4 (Merck), DMF (J. T. Baker), Triethylamine (Merck), sodium chloride (Merck), D-b-glucose (Aldrich), Glucose-oxidase (GOx) type II, from Aspergillus niger (Sigma-Aldrich), aniline-2-sulfonic acid and aniline-3-sulfonic acid (Aldrich) and hydrogen peroxide (Arquimed) were used without further purification. Aniline (Aldrich) was purified by distillation. 0.1 M. Stock glucose solution was prepared in 0.1 M phosphate buffer, 0.1 M NaCl, at pH 7. The glucose solution was prepared every 7 days to allow mutarotation at room temperature before use. The Gox, type II had an activity of 39800 units/g and was stored at -5° C. A 0.1 M phosphate buffer at pH 7.0 (KH2PO4 /K2HPO4) aqueous solution that contained 0.1 M NaCl was prepared by adding an aqueous solution 0.1 M NaOH to a solution of 0.2 M KH2PO4, adjusting the pH and adding solid NaCl.

Electrochemical synthesis of copolymers and entrapment

Modified copolymer electrodes were prepared using potentiostatic oxidation of 15 mi de-aerated aqueous solutions that contained 0.41 M aniline, 0.20 M aniline-2-sulfonic acid (or aniline-3-sulfonic acid) and 0.1 M NaCl as support electrolyte, at 875 mV (vs Ag/AgCl) during 30 minutes on a platinum disc. Previously, the pH of dissolutions was adjusted at 4.90 by addition of aqueous solution 0.1 M NaOH. Then, the electropolymerized films were washed with deionized water to remove unreacted monomer. GOx entrapment was performed under the same conditions, but adding 92 mg (244 U mL-1) of GOx to 15 mi of co-monomeric solution and potentiostatically oxidizing on the platinum disc during 30 minutes. Then, the bio-electrodes were washed with deionized water to allow desorption of the weakly bounded enzyme (or monomer unreacted) from the surface.

Glucose Quantification

Stock b-D-glucose (0.1 M aqueous) was used in several glucose solution preparations, at pH 7.0, at a concentration range of 2.0 - 30.0 mM in 0.1 M phosphate buffer (KH2PO4 /K2HPO4), 0,1 M NaCl. The solutions were saturated with O2 and they were allowed to react during 10 minutes of out-stirring in the presence of bio-electrode (Pt/copolymer/enzyme), and the generated hydrogen peroxide was quantified by cyclic voltammetry in the range of-350 - +1100 mV at a sweep rate of 50 mV/s for four cycles, recording the highest current at 1100 mV (vs Ag/AgCl).

RESULTS AND DISCUSSION

In order to study the bio-electrodes, Platinum disc electrode and copolymeric-electrodes were used as working electrodes for the oxidation of different H2O2 solutions, that contained 0.1 M phosphate buffer and 0.1 M NaCl at pH 7. To determine the oxidation and reduction potentials of hydrogen peroxide, it was used a cyclic voltammetry (CV). Figure 1 shows an oxidation peak located at + 700 mV and a reduction peak located at +198 mV (versus Ag/AgCl). To compare both CV in the presence and absence of H2O2, we have been determined that the peak located at +700 mV correspond at the H2O2oxidation. We have proved, with a platinum disc as working electrode, the quantification of a commercial hydrogen peroxide, using the controlled potential electrochemical method on the maximum peak of oxidation (+700 mV, 30 min). Thus, it was observed a lineal ratio between the peroxide concentration and the charge (Figure 2). However, using the same electrochemical method with copolymeric-electrodes (Pt/copolymers), peroxide quantification was not possible due to the electro-inactivity presented by the working electrodes in the oxidation zone. Nevertheless, using the highest current of the curve of four scans of the voltammogram, we determined an excellent linear relationship between the current and the peroxide concentration for both copolymeric-electrodes. This behavior can be seen in Fig. 3. Besides, the two modified-copolymer electrodes have a lineal current response in respect to hydrogen peroxide concentration up to a limit of 20 mM. This value is the limit of the quantitative measurement of hydrogen peroxide, because the high local concentration of molecular oxygen formed on the interface solution-copolymer makes the peroxide oxidation process difficult. Moreover, the curve's slopes of modified-electrodes are lower at curve's slope of the Pt electrode due to charge transference difficult through of the polymeric material.







Figure 4 shows the quantification of hydrogen peroxide obtained in the process of oxidation of D-glucose using an enzyme entrapped on the copolymeric electrodes. A linear relationship with low hydrogen peroxide concentration (< 20 mM) can be observed in the two curves.


In the polymerization process, the pH decreases in the proximity of the electrode and in this zone, the probability of enzyme deactivation could increase. However, using this type of copolymers, the enzyme remains activated.

For both electrodes, peroxide quantification was possible only for concentration of 20 mM in the presence and absence of enzyme. The results suggest that the presence of the enzyme and the polymer nature are not the limiting factor in peroxide quantification at higher concentrations. Moreover, since the magnitude of the charge response of poly(aniline-co-aniline-3-sulfonic acid) electrode is higher than the poly(aniline-co-aniline-2-sulfonic acid) electrode (in the presence and absence of enzyme), then, the poly(aniline-co-aniline-3-sulfonic acid) electrode has higher electroactivity, possibly due to the higher content of benzenoid units in the copolymer in comparison with poly(aniline-co-aniline-2-sulfonic acid), (Figure 5 and Table 1).




According to the elemental analysis, the results indícate that the composition of the copolymers did not affect the linear range dependence between H2O2 (or D-glucose) concentration and the electrochemical response, but rather the magnitude of the current response.

Finally, the modified-electrodes displayed a fast time of current response, limited by the number of cycles of the CV, 232 s, and enough stability to allow for the measurements after several days.

The functional groups of the copolymers were recorded by FT-IR and UV-Vis spectroscopy. The more important bands in the FT-IR spectra are the C=N stretching, localized at 1588 cm-1 (associated to quinoid groups), the C=C stretching localized at 1495 cm-1 and 1501 cm-1 (associated to benzenoid groups), the S=0 stretching localized at 1147 cm-1 and 1150 cm-1 (associated to sulfonic acid groups), Figure 6. Furthermore, the quinoid and benzenoid groups were detected by UV-Vis absorption spectroscopy. In fact, the bands located at 280 nm and 560 nm were assigned at transitions ππ* (associated to benzenoid groups) and charge-transference transitions (associated to quinoid-diimine groups) respectively15.


Glucose-oxidase has an isoelectric point of 4.2 16 and, therefore at pH over this value the enzyme is negatively charged. Since the copolymers are deposited on an oxidative process, it is favored the electrostatic interactions between these and the enzyme. Another favorable interaction is the dipole-type interaction between the sulfonic acid groups and the enzyme's functional groups. The aniline-sulfonated not homo-polymerized in the oxidative electrochemical process.

CONCLUSIONS

Aniline-2-sulfonic acid, aniline-3-sulfonic acid and aniline were used to prepare copolymers. The monomers properties allowed to use the entrapment method to incorpórate enzyme in copolymers aniline derivatives. In the presence and absence of the enzyme, the copolymers were prepared by the electropolymerization process in aqueous media at pH 4.9. The enzyme was not de-naturalized in the electro-synthesis process.

Using the cyclic voltammetry, the biosensors have linear range dependence between the peroxide (or D-glucose) concentration and the electrochemical response, but only at low concentrations. Thus, the bio-electrodes can be used to quantify D-glucose or peroxide at concentrations lower than 20 mM.

The copolymeric-electrodes showed a good electroactivity at pH 7 using CV method and they could be assayed for other enzymes.

ACKNOWLEDGEMENTS

The authors thank to DID-UACh (Grant S-200407, S-200620) and Fondecyt N° 1080119 for the financial support for this work.

 

REFERENCES

1.- D.D. Borole, U. R. Kapadi, P. P. Mahulikar, D. G. Hundiwale, Polym. Adv. Technol. 15, 306, (2004).         [ Links ]

2.- L. V. Lukahova, A. A. Karyakin, E. E. Karyakina, L. Gorton, Sens. Actuator B. 44, 356, (1997).         [ Links ]

3.- C. Malitesta, F. Palmesano, L. Torsi, P. G. Zambonin, Anal. Chem. 62, 2735, (1990).        [ Links ]

4.- K. Ramanathan, S. S. Pandey, R. Kumar, A. Gulati, N. Murthy, B. D. Mahotra, J. Appl. Polym. Sci. 78, 662, (2000).        [ Links ]

5.- M. Shaolin, H. Huaiguo, Sens. Actuator B Chem. 31, 155 (1996).        [ Links ]

6.- K. Ramanathan, S. Annapoorni, B. D. Malhotra, Sens. Actuators B, 21, 165 (1994).        [ Links ]

7.- A. A. Karyakin, M. Vuki, L. V. Lukachova, E. E. Karyakina, A. V. Orlov, Anal. Chem. 71, 2534 (1999).         [ Links ]

8.- M. Trojanowicz, T. Krawczyski, O. Geschke, K. Cammann, Sens. Actuator B,  28, 191 (1995).        [ Links ]

9.-D. T. Hoa, T. S. Kumar, N. S. Punekar, R. S. Srinivasa, R. Lai, A. Q. Contractor, Anal. Chem. 64, 2645, (1992).         [ Links ]

10.- J. C. Cooper, E. A. H. Hall, Biosens. Bioelectron. 7, 473 (1992)        [ Links ]

11.- T. Ohsaka, Y. Ohnuki, N. Oyama, G. Katayiri, K. Kamisako, J. Electroanal. Chem. 161, 399 (1984)         [ Links ]

12.- N. Gospodinova, L. Terlemezyan, Prog. Polym. Sci. 23, 1443 (1998)         [ Links ]

13.- Y. W. Park, J. S. Moon, M. K. Bak, J. I. Jin, Synth. Met. 29, 389 (1989).         [ Links ]

14.- F. Fusalba, D. Bélanger, J. Phys. Chem. B, 103, 9044 (1999).         [ Links ]

15.- A. Malinauskas, R. Holze, J. Appl. Polym. Sci. 73, 287 (1999)         [ Links ]

16.- R. Bentley, P. D. Boyer, H. A. Lardy, The Enzymes, Academic Press, New York, 1973.        [ Links ]

 

(Received: September 14, 2009 - Accepted: February 1, 2010)

* e-mail: christiansanchez@uach.cl